HEIDENHAIN 2D4-0000 - Start of Python script "" failed

Start of Python script "" failed

The control failed to start a Python script due to communication issues with the PLC. This prevents execution of scripts that rely on PLC data or functionality.

Root Cause Summary

Alarm 2D4-0000 occurs when the TNC control cannot establish proper communication with the PLC to execute a Python script. This typically indicates PLC communication interface failures, incorrect Python script configuration in machine parameters, or missing Python runtime environment setup.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check PLC Connection Status

    Navigate to MOD function → System Info → PLC Status to verify PLC communication state and connection parameters.

    Look for 'PLC Ready' status indicator - anything else indicates communication issues

  2. 2

    Verify Network Configuration

    Access Setup → General → Network Settings and confirm PLC IP address, subnet mask, and gateway settings match your PLC configuration.

    Document current settings before making changes

  3. 3

    Test PLC Ping Response

    Use Setup → Service → Network Diagnostics to ping the PLC IP address and verify physical network connectivity.

    Response times over 10ms may indicate network congestion affecting script startup

  4. 4

    Restart Communication Services

    Execute MOD function → Reset → Communication Reset to reinitialize PLC communication interface without full system restart.

DIY Feasiblemedium confidence

Call a technician if:

  • ·PLC program modifications required
  • ·Python runtime reinstallation needed
  • ·Network infrastructure changes required

Prevention

  • Regularly backup Python scripts and PLC programs
  • Monitor PLC communication status during preventive maintenance
  • Keep Python runtime and TNC software versions synchronized

Common Mistakes

  • Modifying MP7681 without verifying file existence
  • Ignoring PLC cycle time warnings
  • Attempting to run Python scripts without proper licensing