Heidenhain codes
HeidenhainCommunicationIntermediate30-120 minutes

303-000B

HEIDENHAIN 303-000B - Invalid parent node

Invalid parent node

A PLC configuration or communication error has been detected. This affects the interaction between the control and the PLC system.

Root Cause Summary

HEIDENHAIN alarm 303-000B occurs when an OPC UA object configuration references a PLC variable entity as its parent node, which violates the TNC's OPC UA hierarchy structure. This typically happens during OPC UA server configuration or when importing invalid configuration files that create improper parent-child relationships in the communication tree.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access OPC UA Configuration

    Navigate to MOD function → Communication → OPC UA Server → Configuration to examine the current OPC UA node structure.

    Document the current configuration before making changes for rollback purposes.

  2. 2

    Identify Invalid Parent References

    Review the OPC UA object tree and locate any CfgOpcUaObject entries that reference CfgOpcUaPlcVar entities as parent nodes.

    Do not modify configuration while machine programs are running.

  3. 3

    Restructure Node Hierarchy

    Modify the parent reference to point to a valid CfgOpcUaObject or root node instead of the PLC variable entity.

    Use the TNC's built-in configuration validator to check hierarchy before applying changes.

  4. 4

    Restart OPC UA Service

    Cycle the OPC UA server service through MOD → Communication → OPC UA Server → Service Control to apply the corrected configuration.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Configuration file corruption persists after multiple restore attempts
  • ·PLC integration requires custom programming
  • ·Software version update needed

Prevention

  • Always validate OPC UA configurations before importing
  • Maintain proper node hierarchy documentation
  • Regular backup of working OPC UA configurations
  • Test configuration changes in non-production environment first

Common Mistakes

  • Setting PLC variables as parent nodes for OPC UA objects
  • Importing configurations from incompatible TNC versions
  • Not validating configuration files before deployment
  • Modifying OPC UA settings during active machine operation