Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

320-0016

HEIDENHAIN 320-0016 - Data of PLC strobe for channel could not be transferred

Data of PLC strobe for channel could not be transferred

A PLC configuration or communication error has been detected. This affects the interaction between the control and the PLC system.

Root Cause Summary

Alarm 320-0016 occurs when the TNC cannot transfer PLC strobe data to the designated PLC markers for the specified channel. This typically indicates communication issues between the TNC and PLC system or problems with PLC marker configuration.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check PLC Interface Status

    Navigate to MOD function → System Info → PLC Status to verify PLC communication state and interface card status.

    Look for red status indicators or timeout messages in the PLC status display.

  2. 2

    Verify Physical Connections

    Inspect all cables between TNC and PLC interface, checking for loose connections, damaged cables, or corroded contacts on the PLC communication ports.

    Power down both TNC and PLC before checking physical connections.

  3. 3

    Test Communication Parameters

    Access Setup → Machine Parameters → PLC Interface and verify baud rate, protocol settings, and timeout values match PLC configuration.

    Document original settings before making changes for easy rollback.

  4. 4

    Reset PLC Interface

    Perform PLC interface reset via MOD function → Reset → PLC Interface Reset, then monitor for alarm recurrence during next strobe operation.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PLC interface hardware replacement needed
  • ·Complex PLC program modifications required
  • ·Multiple related alarms persist after basic troubleshooting

Prevention

  • Regularly monitor PLC buffer utilization
  • Implement proper PLC marker management practices
  • Schedule periodic PLC interface communication tests
  • Maintain backup copies of working PLC configurations

Common Mistakes

  • Ignoring PLC buffer size limitations
  • Modifying PLC markers without checking dependencies
  • Not verifying PLC program status before troubleshooting TNC
  • Assuming hardware failure without checking software configuration

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.