303-0001

HEIDENHAIN 303-0001 - Referenced OPC UA namespace does not exist

Referenced OPC UA namespace does not exist

The OPC UA configuration references a namespace that does not exist. This prevents creation of the specified nodes and their child elements.

Root Cause Summary

HEIDENHAIN alarm 303-0001 occurs when OPC UA object or variable configurations reference a namespace that doesn't exist in the TNC's OPC UA server configuration. This typically happens after configuration changes, software updates, or incomplete OPC UA setup procedures.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access OPC UA Configuration

    Navigate to MOD function → System Parameters → Communication → OPC UA Server settings in the TNC control.

    Use PLC programming mode for full access to OPC UA parameters

  2. 2

    Verify Namespace Definitions

    Check CfgOpcUaNamespace entries and ensure the namespace referenced in the alarm exists with correct URI and index values.

    Document existing settings before making changes

  3. 3

    Create Missing Namespace

    Add the missing namespace configuration using the TNC's configuration editor, ensuring proper namespace URI and unique index assignment.

  4. 4

    Restart OPC UA Service

    Cycle the OPC UA server service through the TNC system menu to apply namespace changes.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Configuration file corruption requires system-level access
  • ·Software update rollback needed
  • ·Multiple related OPC UA alarms present

Prevention

  • Backup OPC UA configuration before software updates
  • Use namespace URIs instead of fixed indices where possible
  • Document custom namespace configurations
  • Test OPC UA connectivity after any system changes

Common Mistakes

  • Assuming namespace indices remain constant
  • Not restarting OPC UA service after configuration changes
  • Modifying namespace settings without understanding dependencies
  • Ignoring related configuration validation errors