HEIDENHAIN 280-0930 - Starting spindle angle missing
Alarm 280-0930 occurs when the TNC control cannot determine the spindle angle position required for tool imaging or measurement cycles. This typically happens when spindle positioning feedback is missing or the C-axis reference point is not properly established.
HEIDENHAIN 280-0930 - Starting spindle angle missing
Starting spindle angle missing
Tool imaging requires at least one tooth spindle angle to be known. The current data is insufficient.
Root Cause Summary
Alarm 280-0930 occurs when the TNC control cannot determine the spindle angle position required for tool imaging or measurement cycles. This typically happens when spindle positioning feedback is missing or the C-axis reference point is not properly established.
Safety
Causes and Fixes
Check C-axis reference status
Press POS key and verify if C-axis shows REF status. If not referenced, the axis will show dashed lines or question marks.
On newer TNC controls, unreferenced axes are clearly marked with a different color in the position display.
Execute C-axis referencing
Go to Manual Operation mode, select the C-axis (spindle), and press REF+ or REF- to initiate reference point approach.
Ensure no tools or workpieces will interfere with spindle rotation during referencing.
Verify reference completion
Confirm C-axis shows REF status and displays actual angular position values instead of dashes.
The reference process should complete within one full spindle revolution.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.