250-13A7

Heidenhain 250-13A7 - Connection setup to DNC not possible

Connection setup to DNC not possible

Heidenhain TNC error 250-13A7: Connection setup to DNC not possible. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

HEIDENHAIN alarm 250-13A7 occurs when the TNC control cannot establish a connection to the DNC (Distributed Numerical Control) system for file transfer operations. This is typically caused by network configuration issues, incorrect DNC settings in the TNC parameters, or communication protocol mismatches.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Press MOD key, select 'Machine Parameters', navigate to MP7210 series (DNC Interface parameters).

    Always backup current parameters before making changes

  2. 2

    Verify DNC Protocol Settings

    Check MP7210 (DNC protocol type) - should match DNC server configuration (0=LSV-2, 1=FTP, 2=SFTP).

    Incorrect protocol selection will prevent all DNC communication

  3. 3

    Validate Port Configuration

    Verify MP7211 (DNC port number) matches the port configured on DNC server (typically 19000 for LSV-2).

  4. 4

    Test Connection

    Use PGM MGT > DNC > Test Connection to verify parameter changes resolve the alarm.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Network infrastructure changes required
  • ·TNC hardware network interface failure suspected
  • ·Complex enterprise DNC system integration needed

Prevention

  • Document all DNC parameter settings
  • Regularly test DNC connectivity
  • Coordinate with IT before network changes
  • Keep DNC server credentials updated

Common Mistakes

  • Forgetting to save parameters after changes
  • Mixing up LSV-2 and FTP protocol settings
  • Not checking both TNC and server-side configurations
  • Ignoring case sensitivity in usernames/passwords