Heidenhain 250-13A7 - Connection setup to DNC not possible
HEIDENHAIN alarm 250-13A7 occurs when the TNC control cannot establish a connection to the DNC (Distributed Numerical Control) system for file transfer operations. This is typically caused by network configuration issues, incorrect DNC settings in the TNC parameters, or communication protocol mismatches.
Heidenhain 250-13A7 - Connection setup to DNC not possible
Connection setup to DNC not possible
Heidenhain TNC error 250-13A7: Connection setup to DNC not possible. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.
Root Cause Summary
HEIDENHAIN alarm 250-13A7 occurs when the TNC control cannot establish a connection to the DNC (Distributed Numerical Control) system for file transfer operations. This is typically caused by network configuration issues, incorrect DNC settings in the TNC parameters, or communication protocol mismatches.
Safety
Causes and Fixes
Access Machine Parameters
Press MOD key, select 'Machine Parameters', navigate to MP7210 series (DNC Interface parameters).
Always backup current parameters before making changes
Verify DNC Protocol Settings
Check MP7210 (DNC protocol type) - should match DNC server configuration (0=LSV-2, 1=FTP, 2=SFTP).
Incorrect protocol selection will prevent all DNC communication
Validate Port Configuration
Verify MP7211 (DNC port number) matches the port configured on DNC server (typically 19000 for LSV-2).
Test Connection
Use PGM MGT > DNC > Test Connection to verify parameter changes resolve the alarm.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.