HEIDENHAIN 250-1397 - Axis movement canceled
Alarm 250-1397 occurs when a reference run (homing sequence) is interrupted before reaching the reference position. This typically happens due to emergency stops, limit switch activation, encoder issues, or mechanical obstructions during the axis homing process.
HEIDENHAIN 250-1397 - Axis movement canceled
Axis movement canceled
Axis reference motion was interrupted before reaching the target position. The homing procedure could not complete successfully.
Root Cause Summary
Alarm 250-1397 occurs when a reference run (homing sequence) is interrupted before reaching the reference position. This typically happens due to emergency stops, limit switch activation, encoder issues, or mechanical obstructions during the axis homing process.
Safety
Causes and Fixes
Check Emergency Stop Status
Verify all emergency stop buttons are released and check the status display in the TNC control for any active stop conditions.
Ensure machine safety before releasing any emergency stops
Clear Alarm and Reset Reference
Press the CE key to clear the alarm, then navigate to Manual Operation mode and restart the reference run using the REF key for the affected axis.
Check machine parameter MP1010 to verify reference run sequence settings
Monitor Reference Run Completion
Observe the axis movement during reference run to ensure it completes without interruption and reaches the reference mark successfully.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?