HEIDENHAIN 250-13C1 - Pop-up window (Module 9217) not possible
HEIDENHAIN alarm 250-13C1 occurs when PLC Module 9217 attempts to display a pop-up window but the TNC control is in an operating state that prohibits dialog display. This typically happens during active machining cycles, emergency conditions, or when the control is processing critical operations that cannot be interrupted.
HEIDENHAIN 250-13C1 - Pop-up window (Module 9217) not possible
Pop-up window (Module 9217) not possible
PLC pop-up from Module 9217 cannot be shown due to the current operating situation. The display context is incompatible.
Root Cause Summary
HEIDENHAIN alarm 250-13C1 occurs when PLC Module 9217 attempts to display a pop-up window but the TNC control is in an operating state that prohibits dialog display. This typically happens during active machining cycles, emergency conditions, or when the control is processing critical operations that cannot be interrupted.
Safety
Causes and Fixes
Check program execution status
Press STOP key and verify program execution has completely stopped. Check status display shows 'Program stopped' not 'Program interrupted'.
Verify axis and spindle status
Check Machine Status screen (MOD key) to confirm all axes are stationary and spindle is stopped before PLC attempts dialog display.
Reset PLC module timing
Modify PLC program to add delay after detecting program stop before calling Module 9217, typically 500-1000ms delay.
Use PLC marker to track program state changes and trigger pop-up only after confirmed idle state.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.