Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

250-F329

HEIDENHAIN 250-F329 - Monitoring task cannot be displayed.

Monitoring task cannot be displayed.

Monitoring task cannot be displayed due to improper configuration. The task setup violates the minimum limit count or ordering rules.

Root Cause Summary

HEIDENHAIN alarm 250-F329 occurs when monitoring task configuration parameters are incorrectly defined in the machine configuration. This typically involves insufficient limit values, incorrect ordering of threshold parameters, or missing display configuration entries in the CfgMonComponent structure.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access machine configuration menu

    Navigate to Setup → Machine → Configuration → Monitoring → CfgMonPreferences in the TNC control.

    Use MOD function to access configuration mode if not already enabled

  2. 2

    Check monitoringTasks array entries

    Examine each entry in monitoringTasks[] array and verify that exactly four limit values are defined for each monitoring task.

    Document existing values before making changes

  3. 3

    Add missing limit parameters

    Configure all four required limit values (typically warning low, alarm low, alarm high, warning high) for the affected monitoring task entry.

    Reference machine manufacturer specifications for appropriate threshold values

  4. 4

    Save and restart control

    Save configuration changes and perform a control restart to activate the new monitoring task parameters.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Configuration file corruption persists after reset
  • ·Unable to access machine configuration menus
  • ·Monitoring tasks fail after correct parameter configuration

Prevention

  • Regular backup of machine configuration parameters
  • Validate monitoring configuration after TNC software updates
  • Document all monitoring task modifications for future reference

Common Mistakes

  • Entering limit values in wrong sequence
  • Forgetting to configure display parameter
  • Not restarting control after configuration changes
  • Using invalid display format strings