Heidenhain 245-0401 - Failed to send internal message
HEIDENHAIN alarm 245-0401 indicates a failure in internal system communication between TNC control modules, typically involving the NC kernel, PLC, or hardware interface components. This alarm occurs when message queues become corrupted, communication timeouts exceed system limits, or hardware communication paths fail.
Heidenhain 245-0401 - Failed to send internal message
Failed to send internal message
Heidenhain TNC error 245-0401: Failed to send internal message. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.
Root Cause Summary
HEIDENHAIN alarm 245-0401 indicates a failure in internal system communication between TNC control modules, typically involving the NC kernel, PLC, or hardware interface components. This alarm occurs when message queues become corrupted, communication timeouts exceed system limits, or hardware communication paths fail.
Safety
Causes and Fixes
Check System Load Status
Access MOD function, select 'System Info' and check CPU load and memory usage. Look for values exceeding 85% consistently.
Use Ctrl+T to access real-time system diagnostics while alarm is active
Clear NC Memory Buffers
Perform controlled shutdown via MOD > System > Shutdown, wait 30 seconds, then restart. This clears internal message queues.
Ensure all axes are in safe position before shutdown
Verify Program Complexity
Check if alarm occurs with specific programs. Reduce lookahead buffer in machine parameter MP7440 from default 100 to 50.
Complex spline interpolations can overload message buffers
Monitor Communication Timing
In Service menu, check 'Communication Statistics' for message timeout counters and reset if necessary.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.