HEIDENHAIN 235-00AF - Extra inverter at HSCI device
This alarm is triggered by a mismatch between the physical HSCI component topology and the expected configuration defined in the control's system files. The control detected an inverter module on the HSCI bus that either has an incorrect address, is not properly configured in the SIK files, or represents hardware that was added/changed without corresponding software configuration updates.
HEIDENHAIN 235-00AF - Extra inverter at HSCI device
Extra inverter at HSCI device
Extra inverters are connected to an HSCI device that were not configured. Due to ambiguities, the exact extra inverters cannot be precisely identified.
Root Cause Summary
This alarm is triggered by a mismatch between the physical HSCI component topology and the expected configuration defined in the control's system files. The control detected an inverter module on the HSCI bus that either has an incorrect address, is not properly configured in the SIK files, or represents hardware that was added/changed without corresponding software configuration updates.
Safety
Causes and Fixes
Access system configuration mode
Power up the control while holding the MOD key to enter Service/Manufacturing mode. Navigate to MOD → System → Configuration → HSCI Components.
Entering MOD functions requires manufacturer or service-level password. Document existing settings before making changes.
Review current HSCI topology
View the detected devices list showing all components found on HSCI bus. Note the device address (00AF indicates address position) of the unexpected inverter module.
The alarm code suffix (00AF) typically indicates the HSCI address or position where the extra device was detected.
Update SIK configuration file
Edit the SIK5.SYS (or machine-specific SIK file) to add the inverter module definition at the correct address position with proper component type designation (e.g., UM1x4 or UM1x8 depending on model).
Always create a backup of the original SIK file before editing. Save to USB using TNC → File Management → Backup function.
Reload configuration and restart
After saving the updated SIK file, execute a full control restart (power cycle). The control will re-read the configuration and verify the HSCI topology matches the new SIK definition.
Complete restart required - use controlled shutdown procedure to avoid data loss.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.