HEIDENHAIN 231-C210 - C210 Tmax of motor table
HEIDENHAIN alarm 231-C210 occurs when the maximum temperature value (Tmax) in the motor table for the specified axis is incorrectly configured or corrupted. This alarm prevents motor thermal protection from functioning properly and can lead to motor overheating if not corrected.
HEIDENHAIN 231-C210 - C210 Tmax of motor table
C210 Tmax of motor table
This TNC 640 error indicates an internal control fault. The issue relates to Incorrect temperature entry in motor table.
Root Cause Summary
HEIDENHAIN alarm 231-C210 occurs when the maximum temperature value (Tmax) in the motor table for the specified axis is incorrectly configured or corrupted. This alarm prevents motor thermal protection from functioning properly and can lead to motor overheating if not corrected.
Safety
Causes and Fixes
Access motor parameters
Navigate to MOD function → Machine Parameters → MP7210.x where x is the axis number from the alarm message.
Always note the original value before making changes for rollback purposes
Verify Tmax value
Check the current Tmax setting against motor manufacturer specifications. Typical servo motor Tmax values range from 100-155°C.
Never set Tmax higher than motor nameplate specifications
Correct the parameter
Enter the correct Tmax value from motor documentation and execute RESET + START to activate the new parameter.
Cross-reference with MP7200.x (temperature monitoring enable) to ensure monitoring is properly configured
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.