HEIDENHAIN 231-C1D0 - C1D0 Current sensor voltage
HEIDENHAIN alarm 231-C1D0 indicates a current sensor voltage fault in the power module, typically caused by incorrect power module configuration parameters or hardware issues with current measurement circuits. This alarm fires when the TNC detects voltage readings from current sensors that fall outside acceptable operating ranges.
HEIDENHAIN 231-C1D0 - C1D0 Current sensor voltage
C1D0 Current sensor voltage
This TNC 640 error indicates a problem with the power supply system. The control has detected abnormal conditions in the mains power or DC-link voltage.
Root Cause Summary
HEIDENHAIN alarm 231-C1D0 indicates a current sensor voltage fault in the power module, typically caused by incorrect power module configuration parameters or hardware issues with current measurement circuits. This alarm fires when the TNC detects voltage readings from current sensors that fall outside acceptable operating ranges.
Safety
Causes and Fixes
Access Machine Parameters
Navigate to MOD function, select Machine Parameters, enter password level 2 (OEM access).
Incorrect parameter changes can damage drives - document original values before modification
Check Power Module Configuration
Review MP7210 (power module type), MP7211 (rated current), MP7212 (current sensor scaling) for correct values matching your specific power module model.
Cross-reference values with power module nameplate data and Heidenhain documentation
Verify Current Sensor Parameters
Check MP7215 (current sensor offset) and MP7216 (current sensor gain) match factory specifications for your power module variant.
Reset and Test
Save parameters, perform PLC reset via MP7085, and monitor current sensor voltages in diagnostic display MP7800-MP7807.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.