HEIDENHAIN 231-C330 - C330 Motor temp. too high
HEIDENHAIN alarm 231-C330 indicates the motor temperature sensor has detected excessive heat or the temperature monitoring system has failed. This alarm protects the servo motor from thermal damage by monitoring the PTC thermistor or temperature sensor integrated in the motor windings.
HEIDENHAIN 231-C330 - C330 Motor temp. too high
C330 Motor temp. too high
This TNC 640 error indicates an internal control fault. The issue relates to Motor encoder cable defective.
Root Cause Summary
HEIDENHAIN alarm 231-C330 indicates the motor temperature sensor has detected excessive heat or the temperature monitoring system has failed. This alarm protects the servo motor from thermal damage by monitoring the PTC thermistor or temperature sensor integrated in the motor windings.
Safety
Causes and Fixes
Access axis diagnostics
Navigate to MOD function → Diagnosis → Axis to view real-time temperature values and encoder status for the affected axis.
Compare temperature readings between similar axes - a defective cable often shows erratic or impossible temperature values
Inspect encoder cable routing
Check the motor encoder cable for pinching, excessive bending near cable carriers, or damage from metal chips. Pay special attention to areas where the cable enters the motor connector.
Power down the machine before handling encoder cables to prevent damage to sensitive circuits
Measure cable continuity
With machine powered off, use a multimeter to check continuity of temperature sensor wires (typically pins 6 and 7 on standard Heidenhain motor connectors).
Temperature sensor resistance should typically read 1-3kΩ at room temperature for PTC sensors
Verify connector integrity
Inspect the motor connector for corrosion, bent pins, or moisture ingress. Clean contacts with appropriate electrical contact cleaner if contamination is present.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.