Heidenhain codes
HeidenhainPower SupplyIntermediate30-120 minutes

231-8080

HEIDENHAIN 231-8080 - 8080 Uz UV 1xx exceeds max.

8080 Uz UV 1xx exceeds max.

This TNC 640 error indicates an internal control fault. The issue relates to DC-link voltage of the power supply unit too high.

Root Cause Summary

HEIDENHAIN alarm 231-8080 indicates the DC-link voltage in axis 1 has exceeded maximum safe operating limits. This typically occurs when regenerative energy from decelerating motors cannot be properly dissipated through the braking resistor or power supply unit.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Braking Resistor Status

    Navigate to MOD function → Service → Diagnosis → Drive diagnosis and check braking resistor status indicators for axis 1.

    Look for resistance values outside 47-68 ohm range for standard systems

  2. 2

    Measure Braking Resistor Continuity

    Power down system and measure braking resistor resistance with multimeter. Check for open circuit or significantly high resistance values.

    Ensure complete power isolation before resistance measurements

  3. 3

    Inspect Braking Resistor Connections

    Examine all connections to braking resistor terminals, checking for loose connections, corrosion, or burnt contacts at the power supply unit.

    Thermal imaging can reveal hot spots indicating poor connections

  4. 4

    Verify MP1021 Braking Resistor Parameters

    Check machine parameter MP1021 (braking resistor power rating) matches actual installed resistor specifications.

    Incorrect MP1021 values can cause premature braking resistor protection

Service Recommendedmedium confidence

Call a technician if:

  • ·Power supply unit replacement required
  • ·Electrical supply modifications needed
  • ·Multiple related alarms present

Prevention

  • Regular braking resistor inspection
  • Monitor DC-link voltage trends
  • Optimize program deceleration rates
  • Maintain stable mains supply

Common Mistakes

  • Ignoring braking resistor maintenance
  • Programming excessive deceleration rates
  • Overlooking supply voltage quality
  • Incorrect MP1021 parameter settings

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.