Heidenhain 231-806B - 806B Powerfail AC drive cntrller

806B Powerfail AC drive cntrller

Alarm 806B indicates a power failure detected by the AC drive controller (inverter module) that supplies power to the spindle or axis drives. This alarm occurs when the control detects a loss or significant drop in the DC bus voltage within the drive controller, typically due to incoming AC line power interruption or DC bus voltage collapse below the operational threshold.

Root Cause Summary

This alarm specifically indicates that the AC drive controller has detected a power failure condition in its internal DC bus voltage monitoring circuit. The Heidenhain TNC receives this fault status from the drive controller via the digital drive interface, triggering the 806B alarm to prevent machine motion during unsafe power conditions.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Verify AC Input Voltage Stability

    Using a true-RMS multimeter or power quality analyzer, measure all three phases (L1, L2, L3) at the main disconnect feeding the drive controller cabinet. Verify voltage is within 380-420VAC for 400V systems or 440-480VAC for 460V systems. Check for phase imbalance greater than 2%.

    Use the multimeter's MIN/MAX recording function over several minutes to catch intermittent voltage sags that may not be obvious during spot checks.

    Only qualified electricians should work inside the main electrical cabinet. Lethal voltages are present.

  2. 2

    Check Building Power Quality

    Consult with facility maintenance to identify if other equipment experienced power disruptions at the same time. Check for heavy loads on the same circuit (welders, large motors) that could cause voltage sags during startup.

    806B alarms occurring at consistent times (morning startup, shift changes) often point to facility-wide power quality issues rather than machine-specific faults.

  3. 3

    Inspect Main Contactor and Circuit Breakers

    With power OFF, inspect the main line contactor (typically labeled K1 or similar) for contact wear, pitting, or burn marks. Check all circuit breakers for loose mounting or internal failure. Verify proper torque on all AC input terminals per manufacturer specifications.

    Use proper lockout/tagout procedures before opening any electrical panels.

Service Recommendedmedium confidence

Call a technician if:

  • ·High voltage electrical work required
  • ·TNC circuit board replacement needed
  • ·Power quality analysis beyond basic voltage measurement

Prevention

  • Install UPS or power conditioning equipment
  • Perform annual power connection inspections
  • Monitor facility power quality regularly
  • Replace DC bus capacitors on 5-7 year schedule

Common Mistakes

  • Ignoring intermittent voltage drops
  • Using incorrect circuit breaker types
  • Failing to check DC bus capacitor condition
  • Not correlating alarms with facility power events