HEIDENHAIN 231-8310 - 8310 No current in brake test

8310 No current in brake test

This TNC 640 error indicates excessive current draw in the drive system. The control has detected overload conditions that could damage the motor or inverter.

Root Cause Summary

HEIDENHAIN alarm 231-8310 occurs when the TNC control cannot detect proper current flow during the automatic brake test sequence on a servo motor. This typically indicates a failure in the motor brake circuit, power connection issues, or inverter problems preventing the brake coil from energizing correctly.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check motor brake connector

    Inspect the brake connector at the servo motor for loose pins, corrosion, or damage. Verify proper seating of the brake cable connector.

    Ensure machine power is OFF and LOTO procedures are followed before handling electrical connections.

  2. 2

    Measure brake coil resistance

    Using a multimeter, measure resistance across the brake coil terminals. Typical values are 50-200 ohms depending on motor size. Open circuit indicates coil failure.

    Check the motor nameplate or Heidenhain documentation for specific brake coil resistance values for your motor model.

  3. 3

    Inspect brake cable routing

    Trace the brake cable from motor to inverter checking for pinched, cut, or damaged sections especially at cable carriers and bend points.

    Flex the cable while measuring continuity to detect intermittent breaks in stranded conductors.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Inverter replacement required
  • ·Motor brake replacement needed
  • ·Complex parameter configuration issues

Prevention

  • Regular brake cable inspection during PM
  • Monitor brake current trends
  • Proper cable strain relief installation
  • Environmental protection of brake connections

Common Mistakes

  • Testing brake circuits with power on
  • Ignoring intermittent connection issues
  • Incorrect brake voltage parameter settings
  • Skipping insulation resistance testing