HEIDENHAIN 231-8330 - 8330 Brake test was canceled
HEIDENHAIN alarm 231-8330 occurs when the automatic brake test sequence is interrupted or canceled before completion. This safety-critical alarm indicates either PLC intervention, missing enabling signals, or hardware faults preventing proper brake verification on spindle or axis drives.
HEIDENHAIN 231-8330 - 8330 Brake test was canceled
8330 Brake test was canceled
This TNC 640 error relates to the motor brake system. The control has detected an issue with brake operation or testing.
Root Cause Summary
HEIDENHAIN alarm 231-8330 occurs when the automatic brake test sequence is interrupted or canceled before completion. This safety-critical alarm indicates either PLC intervention, missing enabling signals, or hardware faults preventing proper brake verification on spindle or axis drives.
Safety
Causes and Fixes
Check PLC Module 9161 Status
Access TNC diagnostic screen via Setup > General > Diagnostic and navigate to PLC modules. Verify Module 9161 current state and check for value = 0.
Module 9161 controls brake test enabling - value 0 = test disabled, value 1 = test enabled
Analyze PLC Program Logic
Review PLC program sections controlling Module 9161 output. Check for safety interlocks, door switches, or operational mode conditions forcing the module to 0.
Do not bypass safety interlocks - identify and resolve root cause of PLC cancellation
Verify Machine Operating Conditions
Ensure machine is in proper state for brake testing: doors closed, safety circuits active, and no conflicting operations running.
Brake tests typically require machine in safe, idle state with all protective devices active
Reset and Retry Brake Test
After resolving PLC conditions, reset alarm via Setup > General > Error Messages, then initiate new brake test sequence.
Only proceed if all safety conditions are properly satisfied
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.