Heidenhain Controller
System · Intermediate · 30-120 minutes
HEIDENHAIN 231-8620 - 8620 Load is too high
Heidenhain alarm 231-8620 occurs when the servo drive reaches maximum current output but cannot achieve the commanded acceleration or velocity due to excessive mechanical load. This typically indicates mechanical binding, incorrect servo parameters, or drive system overload conditions.
HEIDENHAIN 231-8620 - 8620 Load is too high
8620 Load is too high
This TNC 640 error indicates an internal control fault. The issue relates to Drive has maximum current and cannot accelerate.
Root Cause Summary
Heidenhain alarm 231-8620 occurs when the servo drive reaches maximum current output but cannot achieve the commanded acceleration or velocity due to excessive mechanical load. This typically indicates mechanical binding, incorrect servo parameters, or drive system overload conditions.
Safety
Causes and Fixes
Check Axis Movement Manually
Power down machine and manually move the affected axis to check for binding, excessive friction, or mechanical obstructions.
Ensure machine is properly locked out and axis brakes are released before manual movement
Inspect Way Lubrication
Check lubrication system operation and verify proper oil flow to axis ways and ball screws through MOD 7 diagnostic functions.
Use TNC diagnostic screen to monitor lubrication cycle timing and pressure
Examine Ball Screw and Coupling
Inspect ball screw for damage, contamination, or coupling misalignment that could cause excessive mechanical load.
Listen for unusual noise during slow manual axis movement
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?