Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-4230

Heidenhain 231-4230 - 4230 End of standstill recognition in axis

4230 End of standstill recognition in axis

Heidenhain TNC error 231-4230: 4230 End of standstill recognition in axis. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

Alarm 231-4230 indicates the axis standstill recognition has ended, typically occurring when the servo drive detects unexpected motion or vibration during what should be a stationary period. This alarm is often triggered by mechanical issues, servo parameter mismatches, or encoder feedback problems that prevent proper standstill detection.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check standstill monitoring parameters

    Access MOD function → Machine Parameters → Axis-specific parameters and verify MP1715 STANDSTILL_WINDOW and MP1716 STANDSTILL_TIME settings are appropriate for axis condition.

    Typical standstill window values range from 0.001-0.005mm depending on axis precision requirements

  2. 2

    Perform mechanical inspection

    Manually move axis and check for excessive backlash in ball screw, coupling, and bearing assemblies. Measure backlash with dial indicator.

    Ensure machine is in emergency stop before manual inspection

  3. 3

    Monitor position feedback

    Use TNC diagnostic screen (MOD → Diagnosis → Servo) to observe actual position values during standstill periods for micro-movements exceeding standstill window.

    Look for position drift patterns that indicate specific mechanical wear locations

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Servo drive hardware failure
  • ·Major mechanical repairs needed

Prevention

  • Regular mechanical backlash inspection
  • Periodic encoder cable inspection
  • Environmental vibration monitoring

Common Mistakes

  • Ignoring mechanical wear indicators
  • Adjusting standstill parameters without addressing root cause
  • Overlooking EMI sources near encoder cables

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.