HEIDENHAIN 230-0193 - Position encoder: Amplitude too small
HEIDENHAIN alarm 230-0193 occurs when the position encoder signal amplitude drops below the minimum threshold required for reliable position feedback. This typically indicates contamination on the encoder scale, damaged encoder head, or improper signal cable connections affecting the sinusoidal signal quality.
HEIDENHAIN 230-0193 - Position encoder: Amplitude too small
Position encoder: Amplitude too small
The position-encoder signal amplitude is below the minimum threshold, or the contamination bit is active. This will lead to unreliable position feedback.
Root Cause Summary
HEIDENHAIN alarm 230-0193 occurs when the position encoder signal amplitude drops below the minimum threshold required for reliable position feedback. This typically indicates contamination on the encoder scale, damaged encoder head, or improper signal cable connections affecting the sinusoidal signal quality.
Safety
Causes and Fixes
Power down and inspect encoder scale
Turn off machine power and visually inspect the linear encoder scale for coolant buildup, chips, or oil contamination along the measurement path.
Ensure machine is properly locked out before inspection
Clean encoder scale with approved solvent
Use isopropyl alcohol and lint-free cloth to gently clean the encoder scale surface. Clean in direction parallel to scale graduations, never perpendicular.
Use compressed air to blow debris away from scale before wiping
Inspect and clean scanning head
Check the encoder scanning head for contamination and clean the optical window or magnetic sensor surface using appropriate cleaning materials.
Do not touch optical surfaces with fingers or abrasive materials
Verify signal quality in encoder diagnostics
Power up and check encoder signal amplitude in TNC diagnostic screens under MOD function, encoder diagnostics to confirm signal levels are within specification.
Signal amplitude should typically be >1Vpp for optical encoders
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.