axismd.ai
Heidenhain Controller
Servo/Axis · Intermediate · 30-120 minutes
HEIDENHAIN 230-00D1 - Option for gantry axes not enabled
HEIDENHAIN alarm 230-00D1 occurs when gantry axis configuration parameters are set in machine parameters but the required software option for synchronized gantry operation is not purchased or enabled in the TNC control. The control detects gantry axis configuration but cannot execute the function without the proper license.
HEIDENHAIN 230-00D1 - Option for gantry axes not enabled
Option for gantry axes not enabled
A gantry-axis configuration was activated, but the software option needed for synchronized position coupling is not enabled.
Root Cause Summary
HEIDENHAIN alarm 230-00D1 occurs when gantry axis configuration parameters are set in machine parameters but the required software option for synchronized gantry operation is not purchased or enabled in the TNC control. The control detects gantry axis configuration but cannot execute the function without the proper license.
Safety
Causes and Fixes
Check Active Software Options
Access MOD function, select 'Information about control' and review the active software options list to verify if gantry axis option is enabled.
Document the current option list before contacting Heidenhain for license activation
Verify Machine Parameter Configuration
Check machine parameters MP7500-MP7599 series for gantry axis configuration settings and confirm if gantry axes are defined.
Do not modify machine parameters without proper authorization and backup
Contact Heidenhain for License Activation
Provide control serial number and current software version to Heidenhain service to purchase and activate the gantry axis software option.
Have the machine's purchase order and specifications ready as gantry option may have been ordered but not activated
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.