HEIDENHAIN 126-0133 - Too many CC/UxC devices connected. Current:; permit- ted
This alarm is triggered by a mismatch between the number of CC/UxC motion control devices physically connected or detected on the HSCI bus and the maximum quantity permitted by the control's license or hardware configuration. The control enforces strict limits on the number of motion control modules, and exceeding this limit prevents operation until the configuration is corrected or the license is upgraded.
HEIDENHAIN 126-0133 - Too many CC/UxC devices connected. Current:; permit- ted
Too many CC/UxC devices connected. Current:; permit- ted
An excessive number of CC, UEC, or UMC modules are linked to the HSCI bus, surpassing the system limit. The current count exceeds what the firmware allows for this device category.
Root Cause Summary
This alarm is triggered by a mismatch between the number of CC/UxC motion control devices physically connected or detected on the HSCI bus and the maximum quantity permitted by the control's license or hardware configuration. The control enforces strict limits on the number of motion control modules, and exceeding this limit prevents operation until the configuration is corrected or the license is upgraded.
Safety
Causes and Fixes
Check current license scope
Press MOD key, select 'System Info' → 'Options' or 'License Information'. Document the permitted number of CC/UxC axes shown in the license details.
License information may show 'CC axes: X' or 'UxC modules: X' depending on control generation. Write down the exact permitted quantity.
Compare with detected devices
The alarm message shows 'Current: %1; permitted: %2'. Compare %1 (detected devices) with %2 (licensed devices). If %1 > %2, you have a licensing shortfall.
On iTNC 530 and TNC 620/640 controls, %2 reflects both hardware capability and license restrictions—the lower limit applies.
Obtain license upgrade
Contact the machine tool builder or Heidenhain service with control serial number and required number of CC/UxC axes. Request license upgrade file (typically .LIC or .KEY file).
Never attempt to modify license files manually or use unauthorized license sources—this will corrupt the control software.
Install new license
Load the new license file via MOD → 'System Setup' → 'Load License' or through TNCguide service software. Restart the control to activate the new license scope.
Keep a backup copy of all license files on USB storage—they are tied to control serial number and cannot be regenerated without factory authorization.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.