axismd.ai
Heidenhain Controller
Communication · Intermediate · 30-120 minutes
HEIDENHAIN 126-0132 - Too many HSCI devices connected. Current:; permitted
The control has detected more HSCI-compatible devices (encoders, position measuring systems, or interface modules) than the control model and license permit. This typically results from machine configuration changes, hardware additions without corresponding software licensing, or incorrect device configuration in the control's system files. The control enforces this limit to maintain system performance and match hardware capabilities.
HEIDENHAIN 126-0132 - Too many HSCI devices connected. Current:; permitted
Too many HSCI devices connected. Current:; permitted
The HSCI bus currently has more connected devices than the firmware allows. The actual count exceeds the permitted maximum.
Root Cause Summary
The control has detected more HSCI-compatible devices (encoders, position measuring systems, or interface modules) than the control model and license permit. This typically results from machine configuration changes, hardware additions without corresponding software licensing, or incorrect device configuration in the control's system files. The control enforces this limit to maintain system performance and match hardware capabilities.
Safety
Causes and Fixes
Verify current license configuration
Access MOD > Set-up > Control Info and document the licensed number of axes and encoder interfaces. Compare this with the alarm's permitted value (%2).
The license information shows 'NCK axes' and 'Encoder inputs' separately - both contribute to HSCI device count.
Count physical HSCI devices
In MOD > System Configuration > Device Configuration, review all detected encoders including linear scales, rotary encoders, angle encoders, and touch probe interfaces. Count all EnDat and 1 Vpp devices.
On TNC 640, check both CC (Component Controller) and UMC (Universal Motion Controller) modules for connected devices.
Identify excess devices
Determine which encoders or devices exceed the licensed count. Check if any are unused, redundant, or connected for testing purposes that can be removed.
Do not disconnect encoders on live axes without proper machine shutdown and safety lockout procedures.
Request license upgrade
If all connected devices are required, contact Heidenhain service with your control ID number (from Control Info screen) to purchase additional axis or encoder licenses. Provide current configuration details.
License upgrades are typically delivered as FCL files loaded via TNCopt or SD card - they do not require hardware changes.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.