Heidenhain Controller
Communication · Intermediate · 30-120 minutes
HEIDENHAIN 126-0135 - Too many MB/TE devices connected. Current:; permitted
The TNC control has detected more MB (Bluetooth measuring probe) or TE (electronic touch probe) devices than are permitted by the hardware configuration or software license. This limit is enforced by the control firmware based on model specifications (TNC 320, 530, 620, 640) and active feature licenses. The alarm protects against system resource overload and ensures proper probe management within the control's capacity.
HEIDENHAIN 126-0135 - Too many MB/TE devices connected. Current:; permitted
Too many MB/TE devices connected. Current:; permitted
The number of MB or TE operating panels connected over HSCI is higher than the maximum allowed for this bus.
Root Cause Summary
The TNC control has detected more MB (Bluetooth measuring probe) or TE (electronic touch probe) devices than are permitted by the hardware configuration or software license. This limit is enforced by the control firmware based on model specifications (TNC 320, 530, 620, 640) and active feature licenses. The alarm protects against system resource overload and ensures proper probe management within the control's capacity.
Safety
Causes and Fixes
Check current license status
Press 'MOD' key, navigate to 'TNCdiag' → 'License Information' → 'Feature Licenses'. Look for entries related to 'Probe Systems' or 'Measuring Cycles' and note the permitted quantity.
Document the feature code (FCL) number displayed - you'll need this when contacting Heidenhain for license upgrades.
Review actual connected devices
In MOD mode, go to 'System Settings' → 'Device Configuration' → 'Probe Devices'. The alarm parameters show current devices (%1) vs. permitted (%2). Compare this with your physical setup.
Take a screenshot of this screen before making changes - useful for service documentation.
Disconnect excess probe hardware
Power down the machine. Physically disconnect probe receivers or TE interfaces that exceed the license limit. Ensure only the required number of devices remain connected to PL/HSC inputs or wireless receivers.
Always power down the complete system before disconnecting probe hardware to prevent communication errors or damage.
Request license upgrade if needed
If additional probes are required, contact your Heidenhain distributor with your TNC NC software ID (found in MOD → TNCdiag → System Information) to purchase an upgraded license for additional MB/TE devices.
License upgrades are typically delivered as encrypted files (.lic) that are loaded via USB - no hardware changes required.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.