HEIDENHAIN 126-0112 - Switch-off port on incorrect bus system
This alarm is triggered by a configuration error where safety-critical switch-off outputs are assigned to or detected on an inappropriate bus system within the Heidenhain control architecture. The control's safety monitoring detects this topology violation because switch-off ports must operate on designated safety-rated bus segments (typically the main PLC bus) rather than on encoder or non-safety peripheral buses to maintain functional safety integrity per the control's safety certification requirements.
HEIDENHAIN 126-0112 - Switch-off port on incorrect bus system
Switch-off port on incorrect bus system
The shutdown output was mapped to a bus system that is not allowed for this purpose. Valid choices are external PL units with HSCI link or internal PL assemblies.
Root Cause Summary
This alarm is triggered by a configuration error where safety-critical switch-off outputs are assigned to or detected on an inappropriate bus system within the Heidenhain control architecture. The control's safety monitoring detects this topology violation because switch-off ports must operate on designated safety-rated bus segments (typically the main PLC bus) rather than on encoder or non-safety peripheral buses to maintain functional safety integrity per the control's safety certification requirements.
Safety
Causes and Fixes
Access MOD configuration
Navigate to SYSTEM (MOD key) → Machine Parameters → MOD Settings. Locate the switch-off port configuration section, typically under 'CfgSafetyRelay' or similar safety output parameters.
Make a backup copy of your current MOD file to CF card before making changes - use MOD function → Backup Machine Parameters.
Identify bus assignment
Review the bus node assignment for each switch-off port entry. Look for parameters like 'BusType' or 'NodeAddress' - these should reference PLC bus nodes (typically MC or CC PLC channels), not EIB nodes.
Do not change safety-related parameters without proper authorization and machine manufacturer documentation.
Correct bus assignment
Modify the switch-off port configuration to assign it to the correct PLC bus node. Change bus type from 'EIB' to 'PLC' or update the node address to match the physical safety I/O module location (e.g., CC6xx PLC node instead of EIB encoder node).
Reboot and verify
Perform a complete control restart (power cycle recommended). After reboot, check SYSTEM → Diagnose → PLC → I/O Status to confirm the switch-off port now appears on the correct bus system and alarm clears.
Use Service → System Info → Component Tree to visually verify which bus each component is assigned to after the change.
Call a technician if: