Haas Alarm 315 - Number Exceeds Digit Limit

Too Many Digits

This alarm occurs when the control receives a G-code command with a numeric value containing more digits than the allowed maximum for that address or parameter. The MOCON control has specific digit limits for each address code (X, Y, Z, F, S, etc.) and exceeding these limits triggers this parsing error. The machine will halt program execution at the offending line and require the operator to acknowledge the alarm before proceeding.

Safety

  • Program cannot execute

Common Causes

  • Programming error where a decimal point was omitted, causing values like 0.0001 to be entered as 00001 and exceed digit count limits
  • Post processor configuration issue generating excessive decimal places or improper numeric formatting for feed rates or coordinates
  • Manual MDI entry mistake where operator typed too many digits in a coordinate value or parameter
  • Corrupted program file with garbage characters or malformed numeric data being interpreted as extra digits
  • Macro variable calculation resulting in extremely long numeric string being passed to axis movement or parameter address

Troubleshooting Steps

  1. 1Step 1: Note the exact line number displayed with the alarm and review that specific G-code block for any unusually long numeric values
  2. 2Step 2: Check for missing decimal points in coordinate values, feed rates, or spindle speeds that would make the number appear much larger than intended
  3. 3Step 3: Count the total digits in each address on the problem line and compare to Haas programming manual limits (typically 8 digits including decimal for coordinates, 5-6 for feeds)
  4. 4Step 4: If the program was recently post-processed, verify post processor settings for decimal place output and numeric formatting match Haas control requirements
  5. 5Step 5: Test the suspected line in MDI mode with corrected formatting to confirm the logic is sound before editing the main program
  6. 6Step 6: If alarm persists on a previously working program, perform control software diagnostics and consider reloading the program from verified backup to rule out file corruption

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.