Haas 310 - INVALID G CODE | Haas CNC Alarm
Alarm 310 occurs when the spindle fails to reach the programmed orientation position within the timeout period during M19 or automatic tool change sequences. The NGC control monitors encoder feedback to verify the spindle has settled within the orientation tolerance defined by parameter 78 (SPINDLE ORIENT TOLERANCE).
Haas 310 - INVALID G CODE | Haas CNC Alarm
INVALID G CODE
This alarm occurs when the Haas control encounters a G-code command it does not recognize or support in the current control software version. The control parses each program block and validates G-codes against its internal library; if a code is formatted incorrectly or is not part of the Haas G-code set, execution stops immediately at that line. This protects the machine from executing undefined motion or logic commands that could cause crashes.
Root Cause Summary
Alarm 310 occurs when the spindle fails to reach the programmed orientation position within the timeout period during M19 or automatic tool change sequences. The NGC control monitors encoder feedback to verify the spindle has settled within the orientation tolerance defined by parameter 78 (SPINDLE ORIENT TOLERANCE).
Safety
Causes and Fixes
Check Orientation Timeout Parameter
Navigate to SETTING > PARAMETERS and verify parameter 77 (SPINDLE ORIENT TIME). Default is 5.0 seconds. If spindle is slow to orient, increase to 8-10 seconds.
Monitor actual orientation time using the spindle position display during manual M19 commands
Test Manual Orientation
In MDI mode, execute M19 and observe spindle movement. Time how long it takes to complete orientation and compare to parameter 77 setting.
Ensure no tool is in spindle during manual orientation testing
Verify Spindle Load
Check for excessive spindle load by monitoring spindle motor current during orientation. Heavy toolholders or damaged spindle bearings increase orientation time.
Adjust Timeout if Necessary
If orientation consistently takes longer than parameter 77 setting, increase the timeout value incrementally until reliable operation is achieved.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.