axismd.ai
Haas Controller
System · Intermediate · 20-60 minutes
Haas Alarm 1241 - Chip Auger Jam
Alarm 1241 fires when the chip auger motor current exceeds the programmed limit in Parameter 396 (AUGER CURRENT LIMIT) or when the auger jam sensor detects mechanical obstruction. The NGC control monitors auger motor load through relay R27 and will fault immediately to prevent motor burnout and protect the conveyor drive system.
Haas Alarm 1241 - Chip Auger Jam
Chip Auger Jam
This alarm is triggered when the chip auger motor draws excessive current indicating a mechanical jam or when the auger motor overload relay trips. The MOCON board monitors the auger motor circuit and will fault if current exceeds limits or if feedback from the overload is lost. Automatic operation will halt to prevent damage to the auger drive system.
Root Cause Summary
Alarm 1241 fires when the chip auger motor current exceeds the programmed limit in Parameter 396 (AUGER CURRENT LIMIT) or when the auger jam sensor detects mechanical obstruction. The NGC control monitors auger motor load through relay R27 and will fault immediately to prevent motor burnout and protect the conveyor drive system.
Safety
Causes and Fixes
Power down and lockout machine
Turn main disconnect OFF and follow lockout/tagout procedures before accessing chip conveyor area.
Never attempt to clear jams with power on - rotating auger can cause severe injury
Remove chip pan access covers
Remove the chip pan covers and visually inspect the auger for wrapped chips, long stringy material, or foreign objects blocking rotation.
Use a flashlight to check the entire auger length - jams often occur at the discharge end
Manually clear obstruction
Use chip hooks or pliers to remove wrapped material. Manually rotate auger by hand to verify free movement throughout full rotation.
If auger won't turn by hand, check for bent flights or damaged auger shaft
Test auger operation
Power up machine and test auger using M78 (Chip Auger Forward) command in MDI mode to verify smooth operation before resuming production.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?