Haas Alarm 1210 - Tool Setter Error
Alarm 1210 occurs when the tool setter probe fails to send a trigger signal during G31 skip moves in tool measurement cycles. The control expects a skip signal from the probe contact but receives none before reaching travel limits or timeout thresholds, indicating hardware failure in the probe signal chain or incorrect macro/parameter configuration.
Haas Alarm 1210 - Tool Setter Error
Tool Setter Error
The tool setter error alarm occurs when the spindle-mounted tool setting probe fails to communicate properly with the control system or the probe hardware has detected a fault condition. The MOCON board manages the probe signals and will trigger this alarm if the expected probe response is not received during a tool measurement cycle or if internal probe diagnostics indicate a problem.
Root Cause Summary
Alarm 1210 occurs when the tool setter probe fails to send a trigger signal during G31 skip moves in tool measurement cycles. The control expects a skip signal from the probe contact but receives none before reaching travel limits or timeout thresholds, indicating hardware failure in the probe signal chain or incorrect macro/parameter configuration.
Safety
Causes and Fixes
Visual inspection of probe stylus
Navigate to HANDLE JOG mode and visually inspect the tool setter probe stylus for chips, coolant buildup, or physical damage.
Ensure spindle is stopped and machine is in safe position before inspection
Clean probe stylus
Use compressed air and lint-free cloth with isopropyl alcohol to clean the probe stylus and contact surfaces, removing any coolant residue or debris.
Clean both the stylus tip and the mounting surfaces - contamination anywhere in the contact path will prevent signal transmission
Manual probe test
Press CURRENT COMMANDS, then MDI, enter M75 (probe on) followed by manual stylus deflection while monitoring the PROBE LED on the control panel.
The PROBE LED should illuminate when stylus is manually deflected and extinguish when released
Verify probe spring action
Manually deflect the probe stylus in multiple directions to ensure smooth spring return action and proper mechanical operation.
Use gentle pressure only - excessive force can damage the precision probe mechanism
Call a technician if: