FANUC Alarm SV2 - Low Control Power Voltage (LV)
The FANUC Alarm SV2 - Low Control Power Voltage (LV) is typically caused by insufficient 24VDC supply voltage to the servo amplifier, often due to a failing power supply unit, loose wiring, or excessive load on the 24VDC bus. The most likely fix involves measuring and restoring the correct voltage at the amplifier input terminals or replacing a degraded power supply unit.
FANUC Alarm SV2 - Low Control Power Voltage (LV)
Low Control Power Voltage LV
The control power supply voltage inside the Fanuc Alpha servo amplifier has dropped below the minimum threshold. This alarm (LV) appears on the amplifier's 7-segment display and prevents axis movement. The 24VDC control power supply feeding the amplifier logic circuits is insufficient.
Root Cause Summary
The FANUC Alarm SV2 - Low Control Power Voltage (LV) is typically caused by insufficient 24VDC supply voltage to the servo amplifier, often due to a failing power supply unit, loose wiring, or excessive load on the 24VDC bus. The most likely fix involves measuring and restoring the correct voltage at the amplifier input terminals or replacing a degraded power supply unit.
Causes and Fixes
Measure PSU Output Voltage
Using a digital multimeter set to DC voltage mode, measure the output voltage directly at the 24VDC PSU terminals. Ensure the reading is between 20-28VDC as per Fanuc specifications.
Measure under load by ensuring the machine is powered on with typical operations active to detect voltage drops.
Ensure the machine is in a safe state before accessing live terminals to avoid electrical shock.
Inspect PSU Load Conditions
Check if the PSU is overloaded by reviewing the total current draw of connected devices (servo amplifiers, I/O modules, etc.) against the PSU's rated capacity. Temporarily disconnect non-critical loads and re-measure voltage.
Use a clamp meter to measure current draw on the 24VDC line for a quick load assessment.
Do not disconnect critical safety circuits during testing.
Replace or Repair PSU if Necessary
If the voltage remains below 20VDC or fluctuates significantly, replace the PSU with a compatible unit matching the machine's specifications. Alternatively, send the PSU for repair if replacement is not immediately available.
Keep a spare 24VDC PSU on hand for critical machines to minimize downtime.
Ensure proper grounding when installing a new PSU to prevent electrical noise issues.
Call a technician if: