SV2

FANUC Alarm SV2 - Low Control Power Voltage (LV)

Low Control Power Voltage LV

The control power supply voltage inside the Fanuc Alpha servo amplifier has dropped below the minimum threshold. This alarm (LV) appears on the amplifier's 7-segment display and prevents axis movement. The 24VDC control power supply feeding the amplifier logic circuits is insufficient.

Root Cause Summary

The FANUC Alarm SV2 - Low Control Power Voltage (LV) is typically caused by insufficient 24VDC supply voltage to the servo amplifier, often due to a failing power supply unit, loose wiring, or excessive load on the 24VDC bus. The most likely fix involves measuring and restoring the correct voltage at the amplifier input terminals or replacing a degraded power supply unit.

Causes and Fixes

  1. 1

    Measure PSU Output Voltage

    Using a digital multimeter set to DC voltage mode, measure the output voltage directly at the 24VDC PSU terminals. Ensure the reading is between 20-28VDC as per Fanuc specifications.

    Measure under load by ensuring the machine is powered on with typical operations active to detect voltage drops.

    Ensure the machine is in a safe state before accessing live terminals to avoid electrical shock.

  2. 2

    Inspect PSU Load Conditions

    Check if the PSU is overloaded by reviewing the total current draw of connected devices (servo amplifiers, I/O modules, etc.) against the PSU's rated capacity. Temporarily disconnect non-critical loads and re-measure voltage.

    Use a clamp meter to measure current draw on the 24VDC line for a quick load assessment.

    Do not disconnect critical safety circuits during testing.

  3. 3

    Replace or Repair PSU if Necessary

    If the voltage remains below 20VDC or fluctuates significantly, replace the PSU with a compatible unit matching the machine's specifications. Alternatively, send the PSU for repair if replacement is not immediately available.

    Keep a spare 24VDC PSU on hand for critical machines to minimize downtime.

    Ensure proper grounding when installing a new PSU to prevent electrical noise issues.

DIY Feasiblemedium confidence

Call a technician if:

  • ·If internal servo amplifier failure is suspected and no in-house repair capability exists
  • ·If voltage issues persist after replacing PSU and checking wiring, indicating a deeper electrical fault

Prevention

  • Regularly monitor and log 24VDC PSU output voltage as part of preventive maintenance.
  • Schedule annual inspection of wiring and terminals for corrosion or looseness.
  • Avoid overloading the 24VDC bus by reviewing load capacity before adding new devices.
  • Replace aging PSUs or capacitors proactively in machines over 10 years old.

Common Mistakes

  • Assuming the servo amplifier is faulty without first verifying input voltage at the terminals.
  • Ignoring intermittent voltage drops by not monitoring PSU output over time or under load.

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.