Fanuc Alarm 423 - SERVO ALARM: n AXIS CUMULATIVE TRAVEL EXCEEDED IN TORQUE CONTROL
Alarm 423 occurs during PMC axis control torque mode when the cumulative travel distance of the specified axis exceeds the allowable limit set in parameters. This is a protective function to prevent excessive axis movement during force/torque control operations, commonly used in pressing, grinding, or contouring applications.
Fanuc Alarm 423 - SERVO ALARM: n AXIS CUMULATIVE TRAVEL EXCEEDED IN TORQUE CONTROL
SERVO ALARM: n AXIS EXCESS ERROR AT READY OFF
Position deviation exceeded the allowable limit while the servo was in the Ready-Off state (servo drive not enabled). The axis drifted or was moved while servo power was not applied.
Root Cause Summary
Alarm 423 occurs during PMC axis control torque mode when the cumulative travel distance of the specified axis exceeds the allowable limit set in parameters. This is a protective function to prevent excessive axis movement during force/torque control operations, commonly used in pressing, grinding, or contouring applications.
Safety
Causes and Fixes
Navigate to SYSTEM > PARAM and check parameter 8245 for the faulted axis. This parameter sets the allowable cumulative travel distance in torque control mode (units in detection units).
Review PMC ladder logic and verify the torque control command duration and expected travel distance. Check PMC address G0140-G0143 (torque control command) for proper sequencing.
Increase parameter 8245 value if the process requires greater travel distance, or modify the PMC logic to reset torque control mode before exceeding the limit. Typical values range from 1000 to 50000 depending on application.
Increasing this parameter may reduce protection against runaway conditions in torque control mode
Reset alarm and verify PMC axis control operation. Monitor DIAGNOSIS > PMC AXIS to observe real-time cumulative travel distance during torque control operation.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.