Fanuc Alarm 099 - End of Tape/Rewind
Alarm 099 occurs when the CNC control detects an End of Tape (EOT) signal or rewind condition while attempting to read a program from external memory device, tape reader, or serial communication. This is typically caused by incomplete program data, missing M02/M30 program end code, communication buffer issues, or actual physical end of tape/file reached during DNC/drip feed operations.
Fanuc Alarm 099 - End of Tape/Rewind
Rewind
Fanuc program alarm 099: Rewind. The part program contains an error or illegal condition that the Fanuc control cannot execute. Correct the program to clear this alarm.
Root Cause Summary
Alarm 099 occurs when the CNC control detects an End of Tape (EOT) signal or rewind condition while attempting to read a program from external memory device, tape reader, or serial communication. This is typically caused by incomplete program data, missing M02/M30 program end code, communication buffer issues, or actual physical end of tape/file reached during DNC/drip feed operations.
Safety
Causes and Fixes
Check the NC program in memory or being transferred for proper program end code. Verify program contains M02 (program end) or M30 (program end and rewind) as the final command before the % symbol.
Navigate to SYSTEM > PARAM and check parameter 020 (tape operation settings). Bit 0 controls TV check, bit 4 controls rewind code detection. Ensure settings match your input device type (RS-232, Ethernet, drip feed).
If using DNC/drip feed operation, verify parameter 0020 bit 6 (tape format) and parameter 0101 (input buffer size). Insufficient buffer or incorrect format can cause premature EOT detection.
Re-send or re-load the program ensuring complete file transfer. Check for communication errors in I/O channel diagnostics (SYSTEM > DIAGNOSIS > I/O screen, page to I/O LINK or SERIAL diagnostics).
Ensure program backup before modifying or re-transferring programs to prevent data loss
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.