FANUC codes
FANUCCommunicationIntermediate15-30 minutes

102

Fanuc Alarm 102 - Buffer Overrun

Overrun Error

Fanuc communication alarm 102: Overrun Error. An error was detected on the RS-232 or serial communication interface. Data transmission between the CNC and an external device has failed or was corrupted.

Root Cause Summary

Alarm 102 occurs when the CNC control cannot process incoming serial data fast enough, causing the receive buffer to overflow. This is typically caused by excessive baud rate settings, incorrect communication parameters, or hardware issues with the RS-232 interface preventing proper data flow control.

Safety

  • Data lost

Causes and Fixes

  1. 1

    Check parameter 20 (baud rate setting) on the CNC and verify it matches the external device exactly. Common values are 4800, 9600, or 19200 baud.

  2. 2

    Reduce baud rate to 4800 or 9600 baud on both CNC and external device if currently set higher.

    Record original parameter values before making changes.

  3. 3

    Verify parameter 21 (stop bits), parameter 22 (parity), and parameter 19 (data bits) match between CNC and external device.

  4. 4

    Test communication by sending a small program file (under 10KB) and gradually increase file size if successful.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.