axismd.ai
FANUC Controller
Program/G-code · Basic · 10-20 minutes
Fanuc Alarm 1014 - ILLEGAL FORMAT OF PROGRAM NO.
Alarm 1014 occurs when the CNC control detects an O-code (program number) or N-code (sequence number) address that is not immediately followed by a valid numeric value. This is a program format error that prevents the control from properly identifying program numbers or sequence numbers during program execution or registration.
Fanuc Alarm 1014 - ILLEGAL FORMAT OF PROGRAM NO.
SYSTEM ALARM 1014
Fanuc alarm 1014: SYSTEM ALARM 1014. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 1014 occurs when the CNC control detects an O-code (program number) or N-code (sequence number) address that is not immediately followed by a valid numeric value. This is a program format error that prevents the control from properly identifying program numbers or sequence numbers during program execution or registration.
Causes and Fixes
Navigate to EDIT mode and display the program where the alarm occurred. Press RESET to clear the alarm and check the alarm history (ALARM > HISTORY) to identify the program number if displayed.
Search for O-code addresses at the beginning of the program. Verify format is O#### (e.g., O1234) with no spaces, letters, or special characters between O and the number. Check parameter 3107#0 (8-digit program number) to confirm valid range: 1-9999 if #0=0, or 1-99999999 if #0=1.
Check for orphaned O addresses or O codes with spaces before the number (e.g., 'O 1234' or 'O' on a separate line). Remove spaces and ensure the number immediately follows the O address.
If program was transferred via DNC or USB, verify file encoding is ASCII and check for hidden characters using LIST display on the control (PRGRM > LIST). Re-transfer program if corruption is suspected.
Check parameter 0000#0 (TV check) is set correctly for your system to prevent format errors during program input.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.