Fanuc Alarm 097 - P TYPE NOT ALLOWED (AUTO EXEC)

Memory Overflow

P type cannot be specified when restarting after power ON or after alarms 0094 to 0097 reset, with no automatic operation performed.

Root Cause Summary

Fanuc Alarm 097 occurs when attempting to restart a program using P-code (program number specification) immediately after power-on or after resetting alarms 094-097, without having executed automatic operation first. The system requires at least one complete cycle of automatic operation before allowing P-type restart to establish proper program context and synchronization.

Safety

  • Backup before deleting
  • Backup all important programs and data before deleting anything.
  • Ensure the machine is in a safe state (e.g., powered down or in emergency stop) before performing any memory management tasks.
  • Be aware of the potential for data loss when deleting programs. Double-check that you are deleting the correct files.
  • If upgrading memory, follow the manufacturer's instructions carefully to avoid electrical shock or damage to the machine. Disconnect power before opening any electrical panels.
  • Static discharge can damage electronic components. Use proper grounding techniques when handling memory modules.
  • Backup all data before deleting any programs

Causes and Fixes

  1. 1

    Press RESET to clear alarm 097. Navigate to current program position and verify program is loaded in SYSTEM > PROGRAM display.

  2. 2

    Execute at least one complete automatic cycle in AUTO or MEM mode from program start (no P-type restart) to allow the CNC to establish program flow context.

  3. 3

    After successful automatic operation completion, P-type restart will be enabled. Verify parameter 3109 (restart enable settings) is properly configured if restart functionality is required.

  4. 4

    If restart after power-on is frequently needed, consider using sequence number (N-code) restart instead of P-type restart, or modify operational procedures to include an initial auto cycle after power-on.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Memory hardware failure suspected
  • ·Parameter corruption persists after reset
  • ·Alarm returns after all software solutions attempted

Prevention

  • Maintain adequate free memory (>20%)
  • Avoid P-type restart after power cycles
  • Regular memory cleanup of unused programs
  • Proper system shutdown procedures

Common Mistakes

  • Attempting P-type restart immediately after power-on
  • Ignoring memory usage warnings
  • Loading excessively large programs without memory check
  • Not backing up before memory operations

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.