Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate45-90 minutes

75020

Siemens 75020 - CLC: position offset at lower limit

CLC: position offset at lower limit

The position offset generated by the overlaid motion has reached the limit set in MD $MC_CLC_SENSOR_LOWER_LIMIT or programmed with CLC_LIM(.,.). Depending on the setting in bit 0 of MD $MC_CLC_SPECIAL_FEATURE_MASK the following cancel criterion applies: Bit 0 = 0: Cancel key Bit 0 = 1: Reset key Control reaction: NC Start disable in this channel. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The position offset generated by the overlaid motion has reached the limit set in MD $MC_CLC_SENSOR_LOWER_LIMIT or programmed with CLC_LIM(...,...).
  • Depending on the setting in bit 0 of MD $MC_CLC_SPECIAL_FEATURE_MASK the following cancel criterion applies: Bit 0 = 0: Cancel key Bit 0 = 1: Reset key

Troubleshooting Steps

  1. 1Check position and form of the workpiece.
  2. 2If necessary, program further limits.
  3. 3Clear alarm with the Delete key or NC START. Continuation: Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.