Siemens 75019 - CLC: error ID: , angle

CLC: error ID, angle

The subfunction of the 3D clearance control programmed with CLC(3) "Closed-loop control in programmable direction" reports an error: Error ID: 1:The clearance control direction has not been defined. Probably, [ 0,0,0 ] has been programmed for the three simulated axes specifying the direction components. In the "angle" parameter, zero is output. 2:The max. permissible angle between the orientation of the blast tool and the programmed control direction was exceeded. The permissible angle is set in machine data $MC_CLC_PROG_ORI_MAX_ANGLE. The angle triggering the alarm is output in the 3rd alarm parameter Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The subfunction of the 3D clearance control programmed with CLC(3) "Closed-loop control in programmable direction" reports an error: Error ID: 1:The clearance control direction has not been defined.
  • Probably, [ 0,0,0 ] has been programmed for the three simulated axes specifying the direction components.
  • In the "angle" parameter, zero is output.

Troubleshooting Steps

  1. 1Enlarge the monitoring angle or modify the programming in the part program.
  2. 2Clear alarm with the RESET key. Restart part program