Siemens 61323 - Block : Check 5th digit of _KNUM
Alarm 61323 occurs when the 5th numeric position of the _KNUM parameter contains invalid values during execution of probing cycles (CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998, CYCLE114). The _KNUM variable stores probe kinematic configuration data, and position 5 validates probe offset or compensation selection which must fall within the valid range defined by machine parameters.
Siemens 61323 - Block : Check 5th digit of _KNUM
Block: Check 5th digit of _KNUM
The stated digit of _KNUM includes invalid values. Also check _MVAR
Root Cause Summary
Alarm 61323 occurs when the 5th numeric position of the _KNUM parameter contains invalid values during execution of probing cycles (CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998, CYCLE114). The _KNUM variable stores probe kinematic configuration data, and position 5 validates probe offset or compensation selection which must fall within the valid range defined by machine parameters.
Safety
Causes and Fixes
Access the active probing cycle call in the NC program. Identify the _KNUM assignment statement (typically appears as _KNUM=5xxxx or similar in CYCLE974-CYCLE998 macro invocation).
Ensure you are viewing the correct channel context matching alarm parameter %1.
Verify machine parameter MD 32000 (Probe configuration table entries) and related probe definition parameters (MD 32010-MD 32099). Cross-reference the 5th position value in _KNUM against the valid probe index range configured in these parameters.
Values differ by machine OEM configuration; consult machine documentation for valid probe indices.
Correct the _KNUM assignment to use a valid 5th position value within the range 0 to [max_probe_index-1]. For example, change _KNUM from 52000 to 51000 if only probe indices 0-8 are defined.
Test the corrected cycle block in MDI mode on the affected channel before resuming production program execution.