axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 840D 61258 - Channel block: set parameters for counterspindle chuck in the
Alarm 61258 occurs when the F_SUB_SP cycle attempts to execute counterspindle chuck operations, but the required spindle parameters for the counterspindle have not been configured in the spindle data view. This is a configuration validation error in the NCK that prevents the cycle from initializing proper counterspindle chuck control.
Siemens 840D 61258 - Channel block: set parameters for counterspindle chuck in the
Channel block: set parameters for counterspindle chuck in the
Siemens SINUMERIK alarm 61258: Channel block: set parameters for counterspindle chuck in the. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 61258 occurs when the F_SUB_SP cycle attempts to execute counterspindle chuck operations, but the required spindle parameters for the counterspindle have not been configured in the spindle data view. This is a configuration validation error in the NCK that prevents the cycle from initializing proper counterspindle chuck control.
Safety
Causes and Fixes
Navigate to Diagnostics > Parameters > Spindle View in the SINUMERIK control UI. Verify that a spindle entry exists for the counterspindle (typically spindle index 2 or higher if spindle 1 is main spindle).
Do not confuse the spindle view with general machine data. The spindle view is spindle-specific configuration.
Check SD 32300 (SPIND_TYPE) is set to 2 (counterspindle) and SD 32110 (MAX_SPIND_SPEED) contains a valid maximum RPM value. Verify SD 32400 (SPIND_CTRL_TYPE) is configured appropriately for chuck control.
Confirm MD 20050 (number of spindles) matches the actual spindle count and that the counterspindle is assigned to a valid spindle index within this count.
Save all parameter changes, perform a cold start (POWER OFF > POWER ON), and retry the F_SUB_SP cycle.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.