Siemens 840D 61240 - Channel Block: Wrong feed type
The feed type is not possible for this machining. Alarm triggered by following cycles: F_DRM_DR, F_DRM_PE, F_DRM_RE, F_DRM_SI, F_GROOV, F_MIM_TR, F_ROUGH, F_SP_EF, F_UCUT_T
Siemens 840D 61240 - Channel Block: Wrong feed type
Channel Block: Wrong feed type
The feed type is not possible for this machining. Alarm triggered by following cycles: F_DRM_DR, F_DRM_PE, F_DRM_RE, F_DRM_SI, F_GROOV, F_MIM_TR, F_ROUGH, F_SP_EF, F_UCUT_T
Safety
Refer to Siemens documentation
Ensure qualified technician performs repairs
Common Causes
Feed type parameter mismatch between cycle call and machine configuration
Incompatible feed mode selected (G93/G94/G95) for the active canned cycle
Missing or incorrect feed specification in the NC program block
Machine axis configuration does not support the requested feed type for this cycle
Troubleshooting Steps
1Verify the feed type (G93 inverse time, G94 units/minute, G95 units/revolution) matches the canned cycle requirements in the Siemens documentation
2Check the NC program syntax for the affected canned cycle call and confirm feed parameters are correctly specified
3Review machine configuration and axis kinematics to ensure compatibility with the feed type being used
4Compare the program against a known working example of the same canned cycle with identical feed specifications
5Clear the alarm, reload the program, and execute a single block test to isolate the exact block causing the error