Siemens 840D 4077 - New value of MD not set. Requested bytes too much
Alarm 4077 occurs when attempting to write a new Machine Data (MD) value that would exceed available NCK user memory capacity, preventing the write operation to protect existing user memory contents. This is a memory allocation conflict where the requested MD parameter size plus existing data exceeds the configured memory pool.
Siemens 840D 4077 - New value of MD not set. Requested bytes too much
New value of MD not set. Requested bytes too much
Siemens SINUMERIK 840D system notice 4077: New value of MD not set. Requested bytes too much. This is a system-level notification regarding machine data or configuration. Note the message details and take the indicated action.
Root Cause Summary
Alarm 4077 occurs when attempting to write a new Machine Data (MD) value that would exceed available NCK user memory capacity, preventing the write operation to protect existing user memory contents. This is a memory allocation conflict where the requested MD parameter size plus existing data exceeds the configured memory pool.
Safety
Causes and Fixes
Navigate to Diagnostics > Machine Data > Memory Configuration and note the current NCK user memory utilization percentage and available free space.
Identify the specific MD parameter (%2 in alarm message) and cross-reference its data type and array size in the SINUMERIK documentation. Verify the requested allocation size (%3 bytes) against available pool.
Clear unused tool offsets, geometry data, or custom macro variables via NCK > User Memory > Delete User Data, or reduce the array dimension of the target MD parameter.
Backup all active offsets and configuration data before deletion.
Retry the MD write operation. If persistent, verify MD memory pool size settings (typically MD10200-MD10299 range) are correctly configured for your machine's application needs.