Siemens SINUMERIK Controller
Communication · Intermediate · 30-120 minutes
Siemens 840D 4033 - NOTICE! NCU link communication still not connected
Alarm 4033 indicates that NCU link communication initialization failed because prerequisite system alarms are blocking the communication handshake during boot sequence. The NCK cannot establish the NCU-PLC data link until all blocking alarms are cleared, typically cycle time modification alarms like 4110 that require parameter recalculation.
Siemens 840D 4033 - NOTICE! NCU link communication still not connected
NOTICE! NCU link communication still not connected
Siemens SINUMERIK 840D system notice 4033: NOTICE! NCU link communication still not connected. This is a system-level notification regarding machine data or configuration. Note the message details and take the indicated action.
Root Cause Summary
Alarm 4033 indicates that NCU link communication initialization failed because prerequisite system alarms are blocking the communication handshake during boot sequence. The NCK cannot establish the NCU-PLC data link until all blocking alarms are cleared, typically cycle time modification alarms like 4110 that require parameter recalculation.
Safety
Causes and Fixes
Access Diagnostics menu: NCK > Alarms > Active Alarms. Document all active alarms in the queue, particularly alarm 4110 or cycle time-related alarms (41xx range).
Navigate to Parameters menu: NCK > MD > MD 32100 (CYCLE_TIME_ROUGH_MAIN) and MD 32110 (CYCLE_TIME_FINE_MAIN). Verify values match machine specification sheet and are not showing modified/auto-corrected indicators.
Do not manually edit cycle time parameters without stopping the system and consulting machine documentation.
If alarm 4110 is active, clear it by confirming the NCK cycle time adjustment, then perform a soft reset via Machine > Reset or power cycle the control to reinitialize NCU link communication.
Verify alarm 4033 clears automatically within 30 seconds post-reset. If alarm persists, escalate to check for corrupt startup files or corrupted machine data backup.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.