Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisAdvanced30-90 minutes

4024

Siemens Alarm 4024 - Axis MD Configuration Invalid

Axis Configuration Error

Siemens SINUMERIK 840D system notice 4024: Axis Configuration Error. This is a system-level notification regarding machine data or configuration. Note the message details and take the indicated action.

Root Cause Summary

SINUMERIK alarm 4024 occurs when the NCK detects invalid or inconsistent axis machine data during startup validation. The control system requires complete and logically consistent axis MD parameters for all configured axes, including proper drive assignments and channel allocations.

Safety

  • Axis cannot be used

Causes and Fixes

  1. 1

    Access Machine Data Browser

    Navigate to Commissioning → Machine Data → Axis Data and select the affected axis to review all MD parameters.

    Use the MD search function to quickly locate specific parameters by number

  2. 2

    Verify Critical Axis Parameters

    Check MD30200 (axis type), MD32000 (max velocity), MD32300 (position loop gain), and MD31000 (reference point offset) for valid ranges and proper data types.

    Incorrect MD32300 values can cause servo instability

  3. 3

    Validate Parameter Consistency

    Ensure MD30130 (axis name) matches the configured channel assignment and MD30240 (axis coupling) references exist if configured.

  4. 4

    Reset and Restart NCK

    After correcting invalid parameters, perform NCK Reset via Diagnostics → Service → NCK → Reset to reload machine data.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware failure suspected
  • ·No machine data backup available
  • ·Multiple simultaneous drive communication failures

Prevention

  • Regular machine data backup to CF card
  • Monitor NCU battery voltage quarterly
  • Document all axis parameter changes
  • Use archive comparison tools before major updates

Common Mistakes

  • Modifying axis MD without understanding parameter relationships
  • Ignoring drive assignment validation
  • Not backing up machine data before changes
  • Assuming identical axes have identical MD requirements

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.