Siemens 4026 - Machine data [ ], link axis NC _AX not used by any channel

Machine data, link axis NC_AX not used by any channel

The link axis is not referenced by any channel Control reaction: NC not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Alarms.

Root Cause Summary

This alarm occurs when a link axis defined in machine data is not assigned to any channel, causing a configuration mismatch. Fix it by updating the machine data or channel assignment.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    SAFETY: Power down and lock out system

    Before accessing machine data, ensure the CNC system is in a safe state with emergency stops engaged and proper lockout/tagout procedures followed.

  2. 2

    Check machine data

    Access the machine data settings via the control panel and locate the link axis mentioned in the alarm (%1[%2]). Document current settings before making changes.

  3. 3

    Assign axis to channel

    Ensure the link axis is properly assigned to a channel in the configuration. Verify this change with machine documentation.

  4. 4

    Reset and test

    Save changes, create a backup of new configuration, reset the control, and test with a dry run program to confirm the alarm is cleared.

Service Recommendedmedium confidence

Call a technician if:

  • ·If you are not authorized to modify machine data parameters
  • ·If machine data changes do not resolve the issue
  • ·If you are unsure about axis configuration requirements
  • ·If this is a production-critical machine

Prevention

  • Always backup machine data before making configuration changes
  • Validate machine data and channel assignments during setup with qualified personnel
  • Document axis configurations for reference
  • Implement change control procedures for machine data modifications

Common Mistakes

  • Overlooking the specific axis ID in the alarm message
  • Failing to save changes after updating machine data