Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

4025

Siemens 4025 - Axis : axis container switch not allowed: master/slave active.

Axis: axis container switch not allowed: master/slave active.

It is not possible to enable axis container switch as a master/slave link is active Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • It is not possible to enable axis container switch as a master/slave link is active

Troubleshooting Steps

  1. 1Abort program with the RESET key.
  2. 2If required, disconnect the master - slave coupling.
  3. 3Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.