Siemens 840D 380050 - Profibus-DP: multiple assignment of inputs on address
This alarm occurs due to multiple assignments of input data at the same logical address in the Profibus-DP configuration. Fix by identifying and correcting the duplicate address assignment.
Siemens 840D 380050 - Profibus-DP: multiple assignment of inputs on address
Profibus-DP: multiple assignment of inputs on address
Siemens SINAMICS drive alarm 380050: Profibus-DP: multiple assignment of inputs on address. The encoder or position measuring system connected to the SINAMICS drive has reported a fault. This prevents reliable position feedback for the affected axis.
Root Cause Summary
This alarm occurs due to multiple assignments of input data at the same logical address in the Profibus-DP configuration. Fix by identifying and correcting the duplicate address assignment.
Safety
Causes and Fixes
Check alarm details
Note the logical address mentioned in the alarm message (%1).
Review configuration
Open the Profibus-DP configuration and locate duplicate assignments for the reported address.
Correct assignment
Reassign inputs to unique logical addresses and save the configuration.
Restart system
Clear the alarm and restart the system to apply changes.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.