Siemens 380072 - PROFIBUS/PROFINET: Output slot for basic address (size ) not allowed

PROFIBUS/PROFINET: Output slot for basic address (size) not allowed

An incorrect logical base address was set for a digital or analog output, the area is resides in the access range of the PLC (PIQ, base addresses < 256). For length =1 it is a digital output, For length =2 it is an analog output Control reaction: Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • An incorrect logical base address was set for a digital or analog output, the area is resides in the access range of the PLC (PIQ, base addresses < 256).
  • For length =1 it is a digital output, For length =2 it is an analog output

Troubleshooting Steps

  1. 1Only use addresses outside the PLC process image (e.g. >= 256) for output slots.
  2. 2Enter correct basic addresses in the machine data: - For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
  3. 3For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
  4. 4NCK restart If the error cannot be eliminated by this procedure, please make a note of the error text and contact the control system manufacturer.
  5. 5Switch control OFF - ON. Continuation: Alarms Drive and I/O alarms