axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 310706 - Axis drive maximum working speed invalid
This alarm occurs due to a format overflow caused by high maximum motor speed in drive MD 5401 and speed controller cycle in MD 5001. Fix by adjusting parameters or program settings to prevent overflow.
Siemens 310706 - Axis drive maximum working speed invalid
Axis drive maximum working speed invalid
Because of the high maximum motor speed in the drive MD 5401: DRIVE_MAX_SPEED and the speed controller cycle in MD 5001: SPEEDCTRL_CYCLE_TIME sufficiently high speeds can occur to cause a format overflow Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
This alarm occurs due to a format overflow caused by high maximum motor speed in drive MD 5401 and speed controller cycle in MD 5001. Fix by adjusting parameters or program settings to prevent overflow.
Safety
Causes and Fixes
Check drive parameters
Access MD 5401 and MD 5001 via the control panel to review current settings.
Adjust values
Reduce the maximum speed in MD 5401 or adjust cycle time in MD 5001 to prevent overflow.
Test and restart
Save changes, clear the alarm, and test the program with a dry run.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.