Siemens 840D 310709 - Axis drive error in piston diameter or piston rod diameter
This alarm occurs when the piston diameter or piston rod diameter values in the drive machine data (MD 5131, MD 5132, MD 5133) are invalid, such as a piston diameter less than or equal to zero or a rod diameter exceeding the piston diameter. Correct the values in the respective MD parameters to resolve.
Siemens 840D 310709 - Axis drive error in piston diameter or piston rod diameter
Axis drive error in piston diameter or piston rod diameter
Siemens SINAMICS drive alarm 310709: Axis drive error in piston diameter or piston rod diameter. This alarm indicates a fault condition in the SINAMICS servo drive system. Refer to the Siemens SINAMICS fault list documentation for the complete remedy.
Root Cause Summary
This alarm occurs when the piston diameter or piston rod diameter values in the drive machine data (MD 5131, MD 5132, MD 5133) are invalid, such as a piston diameter less than or equal to zero or a rod diameter exceeding the piston diameter. Correct the values in the respective MD parameters to resolve.
Safety
Causes and Fixes
Access machine data
Navigate to the drive parameters in the Siemens control under MD 5131, MD 5132, and MD 5133.
Verify and correct values
Ensure piston diameter (MD 5131) is greater than zero and greater than rod diameter (MD 5132 or MD 5133).
Save and restart
Save the corrected values, reset the alarm, and restart the system.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.